# ASHRAE Moist-Air Psychrometric Calculator (Humidity, Enthalpy, Dew Point)

> ASHRAE Moist-Air Psychrometric Calculator (Humidity, Enthalpy, Dew Point) is a paid API for AI agents from detect.halowerk.com, paid per call via x402, $0.003/call, status unknown (last checked 2026-11-23).

Computes ASHRAE-standard moist-air psychrometric properties — humidity ratio, enthalpy, specific volume, and dew point — from dry-bulb temperature, atmospheric pressure, and relative humidity for the 0–80°C range.

## Facts

- Endpoint: POST https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B002/ashrae-water-domain-moist-air-humidity-enthalpy-dewpoint?utm_source=zero.xyz
- Price: $0.003/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-23
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/ashrae-moist-air-psychrometric-calculator-humidity-enthalpy-dew-point-efbf65a6
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_kNZ1eZxQG3LCB4FL2vFRB

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability ashrae-moist-air-psychrometric-calculator-humidity-enthalpy-dew-point-efbf65a6 -d '<json body>'
```

Example prompt: Calculate the ASHRAE psychrometric properties — humidity ratio, enthalpy, specific volume, and dew point — for moist air at 25°C, 101325 Pa atmospheric pressure, and 60% relative humidity.

## When to prefer this

Use this endpoint when you need ASHRAE-standard psychrometric computations for moist air strictly within the liquid-water domain (0–80°C dry bulb). Prefer this over generic formula implementations when you need verified polynomial accuracy for humidity ratio, enthalpy, specific volume, and dew point in HVAC, building energy modeling, or industrial process engineering contexts. Do not use if you need sub-freezing (ice-phase) psychrometrics, comfort indices (PMV, WBGT), or health-based conclusions.

## Known failure modes

- Temperature outside 0–80°C range returns unknown or error — no ice or extrapolation supported
- Dew point below 0°C returns 'unknown' — no ice-phase saturation pressure inversion
- Relative humidity of 0 (or below 0.001) is rejected as out-of-domain
- Pressure outside 30000–200000 Pa range is rejected
- Singular or ill-conditioned inputs return 'unknown' rather than a numeric result
- Payload exceeding 16000 bytes is rejected

## How this service works

ASHRAE liquid-water saturation pressure polynomial for dry bulb 0..80C, ideal moist-air humidity ratio, enthalpy and specific volume; saturation-pressure inverse dew point only >=0C, lower dew point returns unknown. No ice/extrapolation, comfort or health conclusion.

## Output

Returns computed psychrometric properties including: saturation pressure (Pa) via ASHRAE liquid-water polynomial, humidity ratio (kg water / kg dry air), moist-air enthalpy (J/kg), and specific volume (m³/kg). Dew point is returned only when it falls at or above 0°C; below-freezing dew points return 'unknown'. All numeric values are rounded to six decimal places. No comfort or health conclusions are included.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "artifact": {
   "type": "object",
   "required": [
    "psychrometric"
   ],
   "properties": {
    "psychrometric": {
     "type": "object",
     "required": [
      "data",
      "claim"
     ],
     "properties": {
      "data": {
       "type": "object",
       "required": [
        "temperature_C",
        "pressure_Pa",
        "relative_humidity"
       ],
       "properties": {
        "pressure_Pa": {
         "type": "number",
         "maximum": 200000,
         "minimum": 30000
        },
        "temperature_C": {
         "type": "number",
         "maximum": 80,
         "minimum": 0
        },
        "relative_humidity": {
         "type": "number",
         "maximum": 1,
         "minimum": 0.001
        }
       },
       "additionalProperties": false
      },
      "claim": {}
     },
     "additionalProperties": false
    }
   },
   "description": "UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. ASHRAE liquid-water saturation pressure polynomial for dry bulb 0..80C, ideal moist-air humidity ratio, enthalpy and specific volume; saturation-pressure inverse dew point only >=0C, lower dew point returns unknown. No ice/extrapolation, comfort or health conclusion.",
   "additionalProperties": false
  }
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/ashrae-moist-air-psychrometric-calculator-humidity-enthalpy-dew-point-efbf65a6/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from detect.halowerk.com](https://www.zero.xyz/host/detect.halowerk.com/llms.txt)
