# BRAINIAC Breaker Rating Check API

> BRAINIAC Breaker Rating Check API is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.03/call, status unknown (last checked 2026-11-12).

Validates circuit breaker ratings against load current, design current, and optional custom rule thresholds using deterministic electrical engineering formulas

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/breaker-rating-check?utm_source=zero.xyz
- Price: $0.03/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/brainiac-breaker-rating-check-api-aca59971
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_7WgqYrDNoh_n435c1VoOS

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability brainiac-breaker-rating-check-api-aca59971 -d '<json body>'
```

Example prompt: Check if a 100A, 3-pole MCCB breaker (ID: BK1) is correctly rated for load L1 drawing 76.4A at 480V, 3-phase with a 1.25 continuous factor — give me the design current and whether the breaker is adequate.

## When to prefer this

Use this endpoint when you need deterministic, formula-based breaker sizing validation using caller-supplied electrical parameters without relying on proprietary standards databases. It is ideal for automated panel schedule audits, design review workflows, or agent-driven electrical checks where you supply voltages, currents, ampacity, and optional custom rule thresholds. Prefer this over manual calculation when processing many loads in one call (up to 500 loads, 200 rules). Note: it does not claim NEC or code compliance and does not invent missing values — suitable for preliminary design validation, not final engineering sign-off.

## Known failure modes

- Missing required voltage or current values — missing values are not invented, so calculations may be incomplete
- Loads or breakers not supplied in recognized fields — unrecognized structure is not parsed
- Exceeding maxItems limits (500 loads, 200 rules) — request will be rejected
- Invalid phase enum value — validation error returned
- CSV or JSON malformed — parsing failure with error response
- Payment not received via x402 — HTTP 402 response before processing

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns a JSON object with an array of breaker check items (one per breaker), each including: breaker ID, type, poles, rating in amps, load current, design current, continuous factor, and boolean flags for adequacy, rating supplied, poles supplied, and code compliance claimed. Also includes overall status, findings array, checkedAt timestamp, breaker count, and a limitations array clarifying that no standards tables are invented and compliance is not claimed.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "items": [
   {
    "type": "MCCB",
    "poles": 3,
    "loadId": "L1",
    "ratingA": 100,
    "adequate": true,
    "breakerId": "BK1",
    "loadCurrentA": 76.414,
    "polesSupplied": true,
    "designCurrentA": 95.5175,
    "ratingSupplied": true,
    "adequateSupplied": true,
    "continuousFactor": 1.25,
    "standardsInvented": false,
    "loadCurrentSupplied": true,
    "codeComplianceClaimed": false,
    "designCurrentSupplied": true,
    "continuousFactorSupplied": true
   }
  ],
  "status": "checked",
  "findings": [],
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "breakerCount": 1,
  "apiKeyRequired": false,
  "paidProviderUsed": false,
  "standardsInvented": false,
  "codeComplianceClaimed": false
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/brainiac-breaker-rating-check-api-aca59971/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)
