# BRAINIAC Power Factor Correction Calculator

> BRAINIAC Power Factor Correction Calculator is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.03/call, status unknown (last checked 2026-11-12).

Calculates required capacitance and reactive power (kVAR) to correct power factor for electrical loads to a specified target power factor

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/power-factor-correction-calculate?utm_source=zero.xyz
- Price: $0.03/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/brainiac-power-factor-correction-calculator-c924197c
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_BnCeK8QDjR0RbwGvNyadX

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability brainiac-power-factor-correction-calculator-c924197c -d '<json body>'
```

Example prompt: Calculate the power factor correction for a 80kW load running at 400V, 50Hz with a current power factor of 0.8 — I need to bring it up to 0.95. Tell me the required kVAR and capacitance in microfarads.

## When to prefer this

Use this endpoint when you need deterministic, formula-based power factor correction calculations without requiring an external standards database or paid engineering data provider. It is well-suited for AI agents doing rapid electrical sizing, energy audits, or utility penalty analysis where the caller supplies all relevant electrical parameters. Prefer this over general LLM math when you need structured JSON output with per-load capacitance values, kVAR requirements, and optional rule-threshold compliance checking via x402 pay-per-call with no account setup.

## Known failure modes

- Missing required load parameters (kW or kVA not supplied) — missing values are not invented, calculation skipped for that load
- Power factor value out of range (must be 0–1) — validation error returned
- Voltage or frequency not supplied and not derivable — calculation cannot proceed without these values
- Loads array empty or malformed — no items returned
- Input exceeds maxItems (500 loads) — request rejected

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns an array of calculated items per load, each with: required kVAR for correction, capacitance in microfarads, supplied/derived voltage and frequency, whether the target power factor was met, the calculated status, any compliance findings against supplied rule thresholds, and disclaimers noting that no standards tables are invented and no code compliance is claimed.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "items": [
   {
    "id": "PF1",
    "kw": 80,
    "voltageV": 400,
    "kwSupplied": true,
    "frequencyHz": 50,
    "powerFactor": 0.8,
    "requiredKvar": 33.7053,
    "capacitanceUF": 670.5456,
    "voltageSupplied": true,
    "frequencySupplied": true,
    "standardsInvented": false,
    "targetPowerFactor": 0.95,
    "capacitanceSupplied": true,
    "powerFactorSupplied": true,
    "requiredKvarSupplied": true,
    "codeComplianceClaimed": false,
    "targetPowerFactorSupplied": true
   }
  ],
  "status": "calculated",
  "findings": [],
  "caseCount": 1,
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "apiKeyRequired": false,
  "paidProviderUsed": false,
  "standardsInvented": false,
  "codeComplianceClaimed": false
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/brainiac-power-factor-correction-calculator-c924197c/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)
