# BRAINIAC Three-Phase Load Balance Check

> BRAINIAC Three-Phase Load Balance Check is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.03/call, status unknown (last checked 2026-11-12).

Analyzes three-phase electrical load data to compute phase currents, imbalance percentage, and flag violations against caller-supplied thresholds or rules.

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/three-phase-load-balance-check?utm_source=zero.xyz
- Price: $0.03/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/brainiac-three-phase-load-balance-check-e3e8a7ba
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_VM4bibYM_DN9gi35in4wS

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability brainiac-three-phase-load-balance-check-e3e8a7ba -d '<json body>'
```

Example prompt: Can you check if my three-phase panel is balanced? Phase A has a 20 kW load at 120V with power factor 0.9, Phase B has a 15 kW load at 120V with power factor 0.9, and Phase C has a 25 kW load at 120V with power factor 0.9 — flag anything over a 10% imbalance threshold.

## When to prefer this

Use this endpoint when you need a deterministic, formula-based three-phase load balance check using caller-supplied data only — no external data providers or invented standards. It is ideal when you already have structured load data (kW, kVA, voltage, current, power factor, phase assignments) and want to quantify imbalance percentage and flag violations against your own thresholds. Prefer this over manual calculation or general-purpose LLMs when you need a structured, auditable result with explicit limitations disclosure.

## Known failure modes

- Missing or incomplete phase data may result in one or more phases showing as not supplied, limiting imbalance computation
- Loads without voltage or current values cannot be used in calculations — missing values are not invented
- Custom rule thresholds not supplied will not be evaluated — no standards tables are auto-applied
- Exceeding the 500-load or 200-rule array limits will cause input rejection
- Malformed CSV, JSON, or base64 file input may result in parse errors

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns per-phase current totals (A) for phases A, B, and C, the computed imbalance percentage, a boolean indicating whether the caller's threshold was met, a list of findings (with codes and details) for any rule violations, the timestamp of the check, and a limitations section clarifying what data sources and assumptions were used.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "status": "checked",
  "findings": [
   {
    "code": "caller_rule_exceeded",
    "kind": "conflict",
    "detail": "Phase imbalance 12.4999% exceeds caller-supplied threshold 10.",
    "subject": "RL-BAL"
   }
  ],
  "phaseA_A": 21.0526,
  "phaseB_A": 18.4211,
  "phaseC_A": 23.6842,
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "maxPhaseA": 23.6842,
  "minPhaseA": 18.4211,
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "imbalancePct": 12.4999,
  "apiKeyRequired": false,
  "phaseASupplied": true,
  "phaseBSupplied": true,
  "phaseCSupplied": true,
  "maxPhaseSupplied": true,
  "minPhaseSupplied": true,
  "paidProviderUsed": false,
  "standardsInvented": false,
  "imbalancePctSupplied": true,
  "codeComplianceClaimed": false,
  "withinCallerThreshold": false,
  "withinCallerThresholdSupplied": true
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/brainiac-three-phase-load-balance-check-e3e8a7ba/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)