# BRAINIAC Transformer Capacity Calculator

> BRAINIAC Transformer Capacity Calculator is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.04/call, status unknown (last checked 2026-11-12).

Calculates transformer loading, capacity adequacy, and electrical parameters for one or more transformers given load, cable, breaker, and rating data.

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/transformer-capacity-calculate?utm_source=zero.xyz
- Price: $0.04/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/brainiac-transformer-capacity-calculator-028b413d
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_Bs8T5zU6zV_j425_gHONj

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability brainiac-transformer-capacity-calculator-028b413d -d '<json body>'
```

Example prompt: Check if our 250 kVA, 11 kV primary / 400 V secondary transformer with 4.5% impedance can adequately handle a 61 kVA load — calculate the loading percentage, primary and secondary currents, and flag whether it's adequate.

## When to prefer this

Use this endpoint when you need a deterministic, formula-based transformer loading calculation without requiring an account, API key, or paid data provider. Ideal for agents performing automated electrical design reviews, feasibility checks, or load-schedule validation where the caller supplies all relevant parameters. Prefer this over general-purpose LLM reasoning for precise numerical outputs (currents, percentages) with traceable inputs. Not suitable when you need actual code-compliance certification or access to proprietary standards tables.

## Known failure modes

- Missing required transformer voltage or kVA fields returns incomplete or erroneous calculations
- Supplying zero or invalid voltages causes division errors or nonsensical current results
- Loads exceeding 500 items are rejected by schema validation
- Input CSV or JSON text that cannot be parsed results in a failed extraction
- Caller omits power factor causing assumed unity factor and potentially inaccurate results
- Rule thresholds not supplied means no compliance flags are generated even if standards apply

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns a JSON object with per-transformer results including: load kVA, loading percentage, primary and secondary currents in amps, adequacy boolean, supplied-value flags for each parameter, findings list, calculation status, timestamp, transformer count, and explicit limitations noting that no external data providers or invented standards tables are used.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "items": [
   {
    "id": "XF1",
    "name": "Main TX",
    "loadKva": 61.3623,
    "adequate": true,
    "primaryV": 11000,
    "ratedKva": 250,
    "loadingPct": 24.5449,
    "secondaryV": 400,
    "impedancePct": 4.5,
    "loadKvaSupplied": true,
    "primaryCurrentA": 13.1216,
    "adequateSupplied": true,
    "primaryVSupplied": true,
    "ratedKvaSupplied": true,
    "secondaryCurrentA": 360.8439,
    "standardsInvented": false,
    "loadingPctSupplied": true,
    "secondaryVSupplied": true,
    "impedancePctSupplied": true,
    "codeComplianceClaimed": false,
    "primaryCurrentSupplied": true,
    "secondaryCurrentSupplied": true
   }
  ],
  "status": "calculated",
  "findings": [],
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "apiKeyRequired": false,
  "paidProviderUsed": false,
  "transformerCount": 1,
  "standardsInvented": false,
  "codeComplianceClaimed": false
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/brainiac-transformer-capacity-calculator-028b413d/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)
