# BRAINIAC Voltage Drop Calculator

> BRAINIAC Voltage Drop Calculator is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.04/call, status unknown (last checked 2026-11-12).

Calculates voltage drop for electrical circuits given loads, cables, and optional compliance rules, returning drop in volts and percentage with findings.

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/voltage-drop-calculate?utm_source=zero.xyz
- Price: $0.04/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/brainiac-voltage-drop-calculator-f095fd69
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_sYDCdWS_vemmlfyPX9g-j

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability brainiac-voltage-drop-calculator-f095fd69 -d '<json body>'
```

Example prompt: Calculate the voltage drop for a three-phase 400V feeder circuit: load is 50 kW at 0.9 power factor, cable is 60 meters of copper, conductor current is 76.4A, and my project spec requires voltage drop to stay under 5%.

## When to prefer this

Use this endpoint when you need deterministic, formula-based voltage drop calculations without needing an external engineering database subscription. Ideal for agents automating electrical design checks, verifying contractor submittals, or enforcing project-specific voltage drop thresholds. Best when caller supplies all voltages, currents, impedances, and cable lengths explicitly. Not suitable when you need NEC/IEC code table lookups, derating from manufacturer data, or formal stamped engineering calculations.

## Known failure modes

- Missing required voltage or current values — calculation skipped for that circuit
- Exceeded max items (500 loads, 200 rules) — request rejected
- Invalid phase enum value — validation error
- Cable or load IDs that don't cross-reference correctly — partial results or unmatched entries
- Malformed base64 file input — parse error
- Payment not confirmed via x402 — 402 response before computation

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns an array of per-circuit voltage drop results including voltage drop in volts and percent, whether each caller-supplied compliance rule threshold was exceeded, cable count, calculation status, timestamp, and a list of limitations (e.g. no external data sources used, no standards tables invented). Findings array surfaces any rule violations or anomalies.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "items": [
   {
    "loadId": "L1",
    "cableId": "CB1",
    "lengthM": 60,
    "currentA": 76.414,
    "voltageV": 400,
    "callerRules": [
     {
      "code": "CALLER-VD",
      "unit": "%",
      "value": 0.6548,
      "ruleId": "RL1",
      "source": "Caller project spec",
      "exceeded": false,
      "threshold": 5,
      "description": "Caller voltage-drop limit",
      "standardsInvented": false,
      "codeComplianceClaimed": false
     }
    ],
    "designation": "Feeder-1",
    "voltageDropV": 2.6194,
    "lengthSupplied": true,
    "voltageDropPct": 0.6548,
    "currentSupplied": true,
    "voltageSupplied": true,
    "standardsInvented": false,
    "voltageDropSupplied": true,
    "codeComplianceClaimed": false,
    "voltageDropPctSupplied": true
   }
  ],
  "status": "calculated",
  "findings": [],
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "cableCount": 1,
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "apiKeyRequired": false,
  "paidProviderUsed": false,
  "standardsInvented": false,
  "codeComplianceClaimed": false
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/brainiac-voltage-drop-calculator-f095fd69/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)