# EV Charger Load Capacity Check

> EV Charger Load Capacity Check is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.04/call, status unknown (last checked 2026-11-12).

Checks whether electrical panels, cables, and breakers have sufficient capacity to support EV charger loads using deterministic formulas against caller-supplied data.

## Facts

- Endpoint: POST https://www.brainiac.software/api/v1/electrical-engineering/ev-charger-load-capacity-check?utm_source=zero.xyz
- Price: $0.04/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-12
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/ev-charger-load-capacity-check-923f433d
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_XLyYz_Y0GCc84JYoaOVkE

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability ev-charger-load-capacity-check-923f433d -d '<json body>'
```

Example prompt: Can you check if my 125A panel at 400V with 40A of existing load can handle two Wallbox EV chargers drawing 32A each as continuous loads, and tell me how much capacity would remain?

## When to prefer this

Use this endpoint when you need a fast, deterministic, no-account electrical load capacity check for EV charger installations and can supply the relevant electrical parameters (voltage, current, panel ratings, existing loads). It is ideal for AI agents doing pre-installation feasibility checks, automated permitting prep, or engineering audits without needing a licensed data provider. It does not invent standards or lookup code tables, so it complements but does not replace a licensed electrical engineer review. Prefer it over manual calculation when processing multiple charger scenarios programmatically at $0.04 per call via x402.

## Known failure modes

- Missing required voltage or current values result in those fields being omitted rather than estimated
- Exceeding 500 load items or 200 rules returns a validation error
- Caller-supplied rules with missing thresholds are skipped silently
- No electrical code tables are referenced — compliance gaps may go unflagged if rules are not supplied
- Malformed base64 file input returns a parse error
- Overly large CSV or JSON inputs (>200KB) are rejected

## How this service works

Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.

## Output

Returns a per-charger adequacy breakdown including total load in amps, design current, existing load, panel capacity, remaining capacity, continuous load factor, voltage supply status, and boolean adequacy flags. Also returns overall status, findings list, limitations disclosures, and metadata flags indicating no paid data provider or invented standards were used.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "csv": {
   "type": "string",
   "maxLength": 200000
  },
  "asOf": {
   "type": "string",
   "maxLength": 40
  },
  "file": {
   "type": "object",
   "required": [
    "mediaType",
    "fileBase64"
   ],
   "properties": {
    "filename": {
     "type": "string",
     "maxLength": 180,
     "minLength": 1
    },
    "mediaType": {
     "enum": [
      "text/plain",
      "text/csv",
      "application/json"
     ],
     "type": "string"
    },
    "fileBase64": {
     "type": "string",
     "maxLength": 12000000,
     "minLength": 1
    }
   },
   "additionalProperties": false
  },
  "json": {
   "type": "string",
   "maxLength": 200000
  },
  "text": {
   "type": "string",
   "maxLength": 200000
  },
  "loads": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "kw": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "kva": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "name": {
      "type": "string",
      "maxLength": 200
     },
     "notes": {
      "type": "string",
      "maxLength": 300
     },
     "phase": {
      "enum": [
       "1",
       "3",
       "A",
       "B",
       "C",
       "AB",
       "BC",
       "CA",
       "ABC"
      ],
      "type": "string"
     },
     "lengthM": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "currentA": {
      "type": "number",
      "maximum": 1000000000,
      "minimum": 0
     },
     "quantity": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "voltageV": {
      "type": "number",
      "maximum": 1000000,
      "minimum": 0
     },
     "continuous": {
      "type": "boolean"
     },
     "powerFactor": {
      "type": "number",
      "maximum": 1,
      "minimum": 0
     }
    },
    "additionalProperties": false
   },
   "maxItems": 500
  },
  "rules": {
   "type": "array",
   "items": {
    "type": "object",
    "properties": {
     "id": {
      "type": "string",
      "maxLength": 80
     },
     "code": {
      "type": "string",
      "maxLength": 80
     },
     "unit": {
      "type": "string",
      "maxLength": 40
     },
     "source": {
      "type": "string",
      "maxLength": 200
     },
     "subject": {
      "type": "string",
      "maxLength": 120
     },
     "threshold": {
      "type": "numb
… (truncated)
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "items": [
   {
    "id": "EV1",
    "name": "Wallbox",
    "adequate": true,
    "quantity": 2,
    "voltageV": 400,
    "totalLoadA": 120,
    "unitCurrentA": 32,
    "existingLoadA": 40,
    "designCurrentA": 80,
    "panelCapacityA": 125,
    "voltageSupplied": true,
    "adequateSupplied": true,
    "continuousFactor": 1.25,
    "standardsInvented": false,
    "totalLoadSupplied": true,
    "remainingCapacityA": 5,
    "unitCurrentSupplied": true,
    "existingLoadSupplied": true,
    "codeComplianceClaimed": false,
    "designCurrentSupplied": true,
    "panelCapacitySupplied": true,
    "continuousFactorSupplied": true,
    "remainingCapacitySupplied": true
   }
  ],
  "status": "checked",
  "findings": [],
  "checkedAt": "2026-11-04T21:00:00.000Z",
  "limitations": [
   "Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
   "No paid engineering data provider is used and no API key is required.",
   "Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
   "Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
   "Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
  ],
  "chargerCount": 1,
  "apiKeyRequired": false,
  "paidProviderUsed": false,
  "standardsInvented": false,
  "codeComplianceClaimed": false
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/ev-charger-load-capacity-check-923f433d/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from www.brainiac.software](https://www.zero.xyz/host/www.brainiac.software/llms.txt)