# FDA Recall & Enforcement Reports Search (openFDA)

> FDA Recall & Enforcement Reports Search (openFDA) is a paid API for AI agents from x402-domain-check.vercel.app, paid per call via x402, $0.02/call, status unknown (last checked 2026-11-13).

Searches FDA recall and enforcement reports for drugs, devices, or food by keyword, returning classification, status, firm, product, reason, distribution, and dates — newest first.

## Facts

- Endpoint: GET https://x402-domain-check.vercel.app/fda/recalls?utm_source=zero.xyz
- Price: $0.02/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-13
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/fda-recall-enforcement-reports-search-openfda-1eaf88f4
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_Re6wcqu4hoiS4coC6lcNw

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability fda-recall-enforcement-reports-search-openfda-1eaf88f4
```

Example prompt: Can you search FDA recall records for 'metformin' in the drug category and show me the top 10 most recent recalls — including their classification, the recalling firm, reason, and distribution area?

## When to prefer this

Choose this endpoint when you need to search FDA recall and enforcement data by keyword across product name, firm name, or recall reason for drugs, devices, or food. It aggregates openFDA data into a clean, structured response with classification and status fields, making it ideal for compliance research, safety monitoring, or due-diligence workflows. Prefer this over raw openFDA API access when you need a pre-parsed, agent-friendly response with a simple keyword search interface and pay-per-call pricing.

## Known failure modes

- Missing required 'q' parameter returns an error (not charged)
- Keyword fewer than 2 or more than 80 characters rejected
- No matching recalls found returns empty recalls array with totalMatches 0
- Invalid 'type' enum value (not drug/device/food) returns validation error
- openFDA upstream service unavailable returns server error (not charged)
- Limit exceeding 25 returns validation error

## How this service works

FDA recall / enforcement reports (openFDA) for drugs, devices or food, searched by keyword across product, reason and firm, newest first: classification (Class I-III), status, firm, product, reason, distribution, dates. Not charged on errors.

## Output

A JSON object containing the search query echo, product type, openFDA source attribution, and an array of recall records each with: recall number, product description, recalling firm, reason for recall, recall classification (Class I/II/III), status (Ongoing/Terminated/etc.), distribution scope, report date, and recall initiation date. Also includes a totalMatches count indicating how many FDA records matched the query.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "$schema": "https://json-schema.org/draft/2020-12/schema",
 "required": [
  "input"
 ],
 "properties": {
  "input": {
   "type": "object",
   "required": [
    "type",
    "method"
   ],
   "properties": {
    "type": {
     "type": "string",
     "const": "http"
    },
    "method": {
     "enum": [
      "GET"
     ],
     "type": "string"
    },
    "queryParams": {
     "type": "object",
     "required": [
      "q"
     ],
     "properties": {
      "q": {
       "type": "string",
       "description": "Keywords: product, firm or reason (2-80 chars)"
      },
      "type": {
       "enum": [
        "drug",
        "device",
        "food"
       ],
       "type": "string",
       "default": "drug"
      },
      "limit": {
       "type": "integer",
       "default": 10,
       "maximum": 25,
       "minimum": 1
      }
     }
    }
   },
   "additionalProperties": false
  },
  "output": {
   "type": "object",
   "required": [
    "type"
   ],
   "properties": {
    "type": {
     "type": "string"
    },
    "example": {
     "type": "object"
    }
   }
  }
 }
}
```

## Response schema (JSON Schema)

```json
{
 "type": "json",
 "example": {
  "q": "listeria",
  "type": "food",
  "source": {
   "name": "openFDA",
   "license": "CC0",
   "disclaimer": "Do not rely on openFDA to make decisions regarding medical care..."
  },
  "recalls": [
   {
    "reason": "Products may be contaminated with Listeria monocytogenes.",
    "status": "Ongoing",
    "product": "Lemon Alfredo Fettuccine…",
    "reportDate": "20261021",
    "distribution": "NY, NJ",
    "recallNumber": "H-0014-2027",
    "recallingFirm": "Example Foods Inc",
    "classification": "Class I",
    "recallInitiationDate": "20260904"
   }
  ],
  "totalMatches": 7498
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/fda-recall-enforcement-reports-search-openfda-1eaf88f4/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from x402-domain-check.vercel.app](https://www.zero.xyz/host/x402-domain-check.vercel.app/llms.txt)
