# Halowerk Pinch Analysis Heat Cascade Minimum Utilities Calculator

> Halowerk Pinch Analysis Heat Cascade Minimum Utilities Calculator is a paid API for AI agents from detect.halowerk.com, paid per call via x402, $0.003/call, status unknown (last checked 2026-11-17).

Computes minimum hot and cold utility targets for a set of process streams using shifted temperature heat cascade (pinch analysis) methodology.

## Facts

- Endpoint: POST https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B001/shifted-temperature-stream-heat-cascade-minimum-utilities?utm_source=zero.xyz
- Price: $0.003/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-17
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/halowerk-pinch-analysis-heat-cascade-minimum-utilities-calculator-3b7d09fc
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_CVyTZaPkIGIKJAtDHA_it

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability halowerk-pinch-analysis-heat-cascade-minimum-utilities-calculator-3b7d09fc -d '<json body>'
```

Example prompt: Run a pinch analysis heat cascade on these three streams with a minimum approach temperature of 10°C: a hot stream from 150°C to 60°C with CP=2.5 kW/°C, a cold stream from 20°C to 130°C with CP=3.0 kW/°C, and another hot stream from 200°C to 80°C with CP=1.8 kW/°C — give me the minimum hot and cold utility targets.

## When to prefer this

Use this endpoint when you need rigorous mathematical pinch analysis (heat cascade method) to establish theoretical minimum utility targets for a set of process streams before designing or retrofitting a heat exchanger network. It is ideal for chemical, refinery, pharmaceutical, or any industrial process engineering context where you have tabulated stream data (supply temperature, target temperature, CP values) and need to apply Linnhoff's pinch methodology computationally. Prefer this over manual spreadsheet calculations or general-purpose math solvers when you need a structured, validated result with pinch point identification.

## Known failure modes

- Invalid stream temperatures outside the range -273 to 10000°C return a validation error
- Heat capacity flow rate of zero or below the minimum threshold (0.000001) causes rejection
- Supplying more than 48 streams exceeds the maxItems limit and returns a schema error
- Supply temperature equal to target temperature may cause degenerate or zero-duty streams
- Negative minimum_approach temperature (below 0) is rejected by schema validation
- Missing required fields (kind, supply, target, heat_capacity_flow) cause 400 errors
- Thermodynamically infeasible cascade configurations may return null or zero utility values

## How this service works

Compute mathematical heat-recovery utility targets from supplied stream tables.

## Output

Returns the minimum hot utility target (QHmin) and minimum cold utility target (QCmin) for the supplied process streams, along with the heat cascade interval breakdown and pinch temperature(s) derived from the shifted temperature composite curves.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "artifact": {
   "type": "object",
   "required": [
    "pinch"
   ],
   "properties": {
    "pinch": {
     "type": "object",
     "required": [
      "data",
      "claim"
     ],
     "properties": {
      "data": {
       "type": "object",
       "required": [
        "minimum_approach",
        "streams"
       ],
       "properties": {
        "streams": {
         "type": "array",
         "items": {
          "type": "object",
          "required": [
           "kind",
           "supply",
           "target",
           "heat_capacity_flow"
          ],
          "properties": {
           "kind": {
            "enum": [
             "hot",
             "cold"
            ]
           },
           "supply": {
            "type": "number",
            "maximum": 10000,
            "minimum": -273
           },
           "target": {
            "type": "number",
            "maximum": 10000,
            "minimum": -273
           },
           "heat_capacity_flow": {
            "type": "number",
            "maximum": 100000,
            "minimum": 0.000001
           }
          },
          "additionalProperties": false
         },
         "maxItems": 48,
         "minItems": 1
        },
        "minimum_approach": {
         "type": "number",
         "maximum": 1000,
         "minimum": 0
        }
       },
       "additionalProperties": false
      },
      "claim": {}
     },
     "additionalProperties": false
    }
   },
   "additionalProperties": false
  }
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/halowerk-pinch-analysis-heat-cascade-minimum-utilities-calculator-3b7d09fc/health.json