# Sensible Two-Stream Heat Exchanger Effectiveness-NTU Outlet Calculator

> Sensible Two-Stream Heat Exchanger Effectiveness-NTU Outlet Calculator is a paid API for AI agents from detect.halowerk.com, paid per call via x402, $0.003/call, status unknown (last checked 2026-11-17).

Computes heat exchanger performance (heat rate, outlet temperatures, capacity ratio) using published epsilon-NTU relationships for counterflow, parallel, and crossflow (both unmixed) configurations with constant fluid capacities.

## Facts

- Endpoint: POST https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B002/sensible-two-stream-effectiveness-ntu-outlet-equilibrium?utm_source=zero.xyz
- Price: $0.003/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-17
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/sensible-two-stream-heat-exchanger-effectiveness-ntu-outlet-calculator-32e2081c
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_mQ_J4YCsNqmJAJ5bbkO1M

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability sensible-two-stream-heat-exchanger-effectiveness-ntu-outlet-calculator-32e2081c -d '<json body>'
```

Example prompt: Calculate the outlet temperatures and heat transfer rate for a counterflow heat exchanger with UA = 5000 W/K, hot side inlet at 400 K with capacity rate 8000 W/K, and cold side inlet at 300 K with capacity rate 6000 W/K.

## When to prefer this

Use this endpoint when you need fast, analytically exact epsilon-NTU heat exchanger performance calculations for sensible (no phase change), constant-capacity-rate two-stream exchangers in counterflow, parallel, or crossflow (both unmixed) configurations. It is ideal for engineering design checks, sizing validation, and parametric studies where computational accuracy and explicit handling of edge cases (zero UA, equal capacities in counterflow) matter. Prefer it over general numerical simulation when the configuration is one of the three supported types and fluid properties can be treated as constant.

## Known failure modes

- UA, capacity rates, or temperatures outside allowed bounds (0–10,000,000 W/K for UA; 150–2000 K for temperatures) return validation errors
- Condensation or phase change scenarios are out of scope and results will be invalid
- Ill-conditioned or degenerate inputs may return unknown/undefined results per schema
- Configurations other than counter, parallel, or cross_both_unmixed are rejected
- Payload exceeding 16,000 bytes artifact limit returns an error
- Missing required fields (configuration, UA, hot_capacity, cold_capacity, hot_inlet, cold_inlet) cause rejection

## How this service works

Published sensible constant-capacity epsilon NTU relationships for counterflow, parallel and crossflow both unmixed in one capability; explicit zero UA and equal counterflow capacity limits. Return heat rate, outlet temperatures, capacity ratio. No condensation or changing properties.

## Output

Returns the computed heat transfer rate (W), hot and cold stream outlet temperatures (K), capacity ratio (Cmin/Cmax), effectiveness (epsilon), and NTU for the specified heat exchanger configuration and operating conditions. Numeric results are rounded to six decimal places. Edge cases like zero UA or equal capacity rates in counterflow are handled explicitly.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "artifact": {
   "type": "object",
   "required": [
    "heatExchanger"
   ],
   "properties": {
    "heatExchanger": {
     "type": "object",
     "required": [
      "data",
      "claim"
     ],
     "properties": {
      "data": {
       "type": "object",
       "required": [
        "configuration",
        "UA",
        "hot_capacity",
        "cold_capacity",
        "hot_inlet",
        "cold_inlet"
       ],
       "properties": {
        "UA": {
         "type": "number",
         "maximum": 10000000,
         "minimum": 0
        },
        "hot_inlet": {
         "type": "number",
         "maximum": 2000,
         "minimum": 150
        },
        "cold_inlet": {
         "type": "number",
         "maximum": 2000,
         "minimum": 150
        },
        "hot_capacity": {
         "type": "number",
         "maximum": 10000000,
         "minimum": 0.001
        },
        "cold_capacity": {
         "type": "number",
         "maximum": 10000000,
         "minimum": 0.001
        },
        "configuration": {
         "enum": [
          "counter",
          "parallel",
          "cross_both_unmixed"
         ]
        }
       },
       "additionalProperties": false
      },
      "claim": {}
     },
     "additionalProperties": false
    }
   },
   "description": "UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. Published sensible constant-capacity epsilon NTU relationships for counterflow, parallel and crossflow both unmixed in one capability; explicit zero UA and equal counterflow capacity limits. Return heat rate, outlet temperatures, capacity ratio. No condensation or changing properties.",
   "additionalProperties": false
  }
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/sensible-two-stream-heat-exchanger-effectiveness-ntu-outlet-calculator-32e2081c/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from detect.halowerk.com](https://www.zero.xyz/host/detect.halowerk.com/llms.txt)