# Solution-Diffusion Osmosis Coupled Film Polarization Flux Solver

> Solution-Diffusion Osmosis Coupled Film Polarization Flux Solver is a paid API for AI agents from detect.halowerk.com, paid per call via x402, $0.003/call, status unknown (last checked 2026-11-17).

Numerically solves for coupled permeate flux and membrane surface concentration in reverse osmosis using solution-diffusion transport with concentration polarization film theory.

## Facts

- Endpoint: POST https://detect.halowerk.com/v1/F-TD2000-GEO-INDUSTRY-B009/solution-diffusion-osmosis-coupled-film-polarization-flux-root?utm_source=zero.xyz
- Price: $0.003/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-17
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/solution-diffusion-osmosis-coupled-film-polarization-flux-solver-2d4debf0
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_taoYDCDGXu3YyNgtiTJ-I

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability solution-diffusion-osmosis-coupled-film-polarization-flux-solver-2d4debf0 -d '<json body>'
```

Example prompt: Solve the coupled permeate flux and membrane surface concentration for a reverse osmosis system with water permeance 1e-12 m/(Pa·s), solute permeance 1e-7 m/s, film mass transfer coefficient 2e-5 m/s, bulk molar density 55500 mol/m³, applied pressure difference 5000000 Pa, and temperature 298 K.

## When to prefer this

Use this endpoint when you need a physically rigorous, coupled solution to the reverse osmosis permeate flux and concentration polarization problem using the solution-diffusion model with film theory — particularly when concentration polarization effects are significant and cannot be decoupled. It is preferred over simplified flux calculators when membrane surface concentration is itself needed as an output, or when transport coefficients are known explicitly and osmotic pressure must be computed self-consistently.

## Known failure modes

- Input parameters outside physical bounds (e.g. water_permeance > 1e-9 or temperature outside 200–500 K range) will be rejected with validation errors
- Numerical root-finding may fail to converge if transport coefficient combinations are physically inconsistent or extreme, returning a convergence error
- Missing required fields (any of the six transport parameters) will result in a 400-class error
- Negative or zero pressure difference may cause solver instability or immediate rejection

## How this service works

Resolve the coupled permeate flux and membrane concentration from explicit transport coefficients.

## Output

Returns the numerically resolved permeate flux (water flux through the membrane) and the membrane surface solute concentration, accounting for the coupling between solution-diffusion transport and concentration polarization film theory. These values enable determination of effective rejection, osmotic pressure at the membrane wall, and system performance metrics.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "properties": {
  "artifact": {
   "type": "object",
   "required": [
    "reverseOsmosis"
   ],
   "properties": {
    "reverseOsmosis": {
     "type": "object",
     "required": [
      "data",
      "claim"
     ],
     "properties": {
      "data": {
       "type": "object",
       "required": [
        "water_permeance",
        "solute_permeance",
        "film_mass_transfer",
        "bulk_molar_density",
        "pressure_difference",
        "temperature_kelvin"
       ],
       "properties": {
        "water_permeance": {
         "type": "number",
         "maximum": 1e-9,
         "minimum": 1e-15
        },
        "solute_permeance": {
         "type": "number",
         "maximum": 0.001,
         "minimum": 1e-10
        },
        "bulk_molar_density": {
         "type": "number",
         "maximum": 10000,
         "minimum": 0.000001
        },
        "film_mass_transfer": {
         "type": "number",
         "maximum": 0.01,
         "minimum": 1e-8
        },
        "temperature_kelvin": {
         "type": "number",
         "maximum": 500,
         "minimum": 200
        },
        "pressure_difference": {
         "type": "number",
         "maximum": 100000000,
         "minimum": 1
        }
       },
       "additionalProperties": false
      },
      "claim": {}
     },
     "additionalProperties": false
    }
   },
   "additionalProperties": false
  }
 }
}
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/solution-diffusion-osmosis-coupled-film-polarization-flux-solver-2d4debf0/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from detect.halowerk.com](https://www.zero.xyz/host/detect.halowerk.com/llms.txt)
