# Three-Phase Power Calculator

> Three-Phase Power Calculator is a paid API for AI agents from electrical-calc.x402tookit.com, paid per call via x402, $0.02/call, status unknown (last checked 2026-11-02).

Calculates balanced three-phase kW, kVA, kVAR, power factor, and line/phase currents from voltage and one of current, kW, or kVA.

## Facts

- Endpoint: GET https://electrical-calc.x402tookit.com/three-phase-power?utm_source=zero.xyz
- Price: $0.02/call
- Payment: x402
- Status: unknown
- Last checked: 2026-11-02
- Activations on Zero: 0
- Tags: x402
- Canonical page: https://www.zero.xyz/c/three-phase-power-calculator-a7a1ad21
- Structured record (JSON): https://api.zero.xyz/v1/capabilities/cap_rz2MwCo6kN0Jwd9RL7jMn

Status and success rate cover calls made through Zero and Zero's own probes. Third-party monitors may report differently.

## How to call it through Zero

Zero handles the 402 payment challenge and records the run. With the Zero CLI installed (`npm i -g @zeroxyz/cli`):

```sh
zero fetch --capability three-phase-power-calculator-a7a1ad21
```

Example prompt: What's the kVA, kVAR, and line current for a balanced three-phase load drawing 75 kW at 415 V line-to-line with a power factor of 0.85?

## When to prefer this

Use this endpoint when you need a complete set of three-phase AC power quantities (kW, kVA, kVAR, line current, phase angle) from a known voltage and any one of current, kW, or kVA. Ideal for electrical engineers sizing generators, switchgear, transformers, or cables for balanced three-phase industrial loads. Prefer this over manual calculation or generic math tools when you need all derived quantities in a single call with consistent units and named fields.

## Known failure modes

- Missing required voltageV parameter returns a validation error
- Providing more than one of currentA, kw, or kva results in ambiguous input error
- Power factor outside (0, 1] range causes a validation failure
- Zero or negative voltage value rejected as invalid
- Providing none of currentA, kw, or kva results in insufficient input error

## How this service works

Balanced three-phase kW, kVA, kVAR and line and phase current from voltage, power factor and one of current, kW or kVA.

## Output

Returns a JSON object with the full set of three-phase power quantities: real power (kW), apparent power (kVA), reactive power (kVAR), power factor, line current (A), phase angle in degrees, wye phase voltage (V), delta phase current (A), kW per phase, input mode used, and a human-readable summary. Fields not computable from the given input are returned as null.

## Request schema (JSON Schema)

```json
{
 "type": "object",
 "$schema": "https://json-schema.org/draft/2020-12/schema",
 "required": [
  "input"
 ],
 "properties": {
  "input": {
   "type": "object",
   "required": [
    "type",
    "method"
   ],
   "properties": {
    "type": {
     "type": "string",
     "const": "http"
    },
    "method": {
     "enum": [
      "GET"
     ],
     "type": "string"
    },
    "queryParams": {
     "type": "object",
     "required": [
      "voltageV"
     ],
     "properties": {
      "kw": {
       "type": "number",
       "description": "Real power in kilowatts (send exactly one of currentA, kw, kva)"
      },
      "kva": {
       "type": "number",
       "description": "Apparent power in kVA (send exactly one of currentA, kw, kva)"
      },
      "currentA": {
       "type": "number",
       "description": "Line current in amperes (send exactly one of currentA, kw, kva)"
      },
      "voltageV": {
       "type": "number",
       "description": "Line-to-line voltage in volts"
      },
      "powerFactor": {
       "type": "number",
       "description": "Power factor above 0 to 1 (default 1; not needed when kw and kva are both implied)"
      }
     }
    }
   },
   "additionalProperties": false
  },
  "output": {
   "type": "object",
   "required": [
    "type"
   ],
   "properties": {
    "type": {
     "type": "string"
    },
    "example": {
     "type": "object",
     "properties": {
      "kw": {
       "type": [
        "null",
        "number"
       ]
      },
      "kva": {
       "type": [
        "null",
        "number"
       ]
      },
      "asOf": {
       "type": [
        "null",
        "string"
       ]
      },
      "kvar": {
       "type": [
        "null",
        "number"
       ]
      },
      "source": {
       "type": [
        "null",
        "string"
       ]
      },
      "reasons": {
       "type": [
        "array",
        "null"
       ],
       "items": {
        "type": "string"
       }
      },
      "summary": {
       "type": [
        "null",
        "string"
       ]
      },
      "verdict": {
       "type": [
        "null",
        "string"
       ]
      },
      "degraded": {
       "type": [
        "boolean",
        "null"
       ]
      },
      "inputMode": {
       "type": [
        "null",
        "string"
       ]
      },
      "disclaimer": {
       "type": [
        "null",
        "string"
       ]
      },
      "kwPerPhase": {
       "type": [
        "null",
        "number"
       ]
    
… (truncated)
```

## More

- Live health (JSON, refreshed every minute): https://www.zero.xyz/c/three-phase-power-calculator-a7a1ad21/health.json
- [Zero catalog index](https://www.zero.xyz/llms.txt)
- [Other services from electrical-calc.x402tookit.com](https://www.zero.xyz/host/electrical-calc.x402tookit.com/llms.txt)
