BRAINIAC Power Factor Correction Calculator is a paid API for AI agents from www.brainiac.software, paid per call via x402, $0.03/call, status unknown (last checked 2026-11-12).
Calculates required capacitance and reactive power (kVAR) to correct power factor for electrical loads to a specified target power factor
Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.
Returns an array of calculated items per load, each with: required kVAR for correction, capacitance in microfarads, supplied/derived voltage and frequency, whether the target power factor was met, the calculated status, any compliance findings against supplied rule thresholds, and disclaimers noting that no standards tables are invented and no code compliance is claimed.
POSThttps://www.brainiac.software/api/v1/electrical-engineering/power-factor-correction-calculate?utm_source=zero.xyzUse this endpoint when you need deterministic, formula-based power factor correction calculations without requiring an external standards database or paid engineering data provider. It is well-suited for AI agents doing rapid electrical sizing, energy audits, or utility penalty analysis where the caller supplies all relevant electrical parameters. Prefer this over general LLM math when you need structured JSON output with per-load capacitance values, kVAR requirements, and optional rule-threshold compliance checking via x402 pay-per-call with no account setup.
| Field | Type | Description |
|---|---|---|
| csv | string | |
| asOf | string | |
| file | object | |
| json | string | |
| text | string | |
| loads | array | |
| rules | array | |
| cables | array | |
| system | object | |
| breakers | array | |
| chargers | array | |
| generators | array | |
| transformers | array | |
| powerFactorCases | array |
{
"type": "json",
"example": {
"items": [
{
"id": "PF1",
"kw": 80,
"voltageV": 400,
"kwSupplied": true,
"frequencyHz": 50,
"powerFactor": 0.8,
"requiredKvar": 33.7053,
"capacitanceUF": 670.5456,
"voltageSupplied": true,
"frequencySupplied": true,
"standardsInvented": false,
"targetPowerFactor": 0.95,
"capacitanceSupplied": true,
"powerFactorSupplied": true,
"requiredKvarSupplied": true,
"codeComplianceClaimed": false,
"targetPowerFactorSupplied": true
}
],
"status": "calculated",
"findings": [],
"caseCount": 1,
"checkedAt": "2026-11-04T21:00:00.000Z",
"limitations": [
"Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.",
"No paid engineering data provider is used and no API key is required.",
"Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.",
"Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.",
"Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."
],
"apiKeyRequired": false,
"paidProviderUsed": false,
"standardsInvented": false,
"codeComplianceClaimed": false
}
}No reviews yet. Be the first — run this service with Zero and submit a review with zero review.