HVAC Coil Load Calculator is a paid API for AI agents from x402-agent-api.onrender.com, paid per call via x402, $0.002/call, status unknown (last checked 2026-10-10).
Calculates sensible, latent, and total HVAC coil loads (BTU/MBH/tons), SHR, and condensate from airflow and entering/leaving air states, with full ASHRAE psychrometric step-by-step workings.
HVAC coil load calculator: from airflow and entering/leaving air (any two properties each), the sensible, latent and total load, tons, SHR and condensate; or one state plus loads to solve the other. Outdoor/return air mixing and outdoor air % back-calculation. ASHRAE psychrometrics, elevation, IP or SI. Shows every step with the numbers. $0.002 USDC per call.
Returns a JSON object with the resolved entering and leaving air psychrometric states (dry bulb, wet bulb, dew point, RH, humidity ratio, enthalpy, grains, density, specific volume, vapor pressure), coil loads object (sensible, latent, total in MBH or kW, tons, SHR, total from enthalpy), condensate rate, atmospheric pressure, elevation, mode, units, unit labels, step-by-step ASHRAE calculation array with references, any notes, and suggested next tool calls.
POSThttps://x402-agent-api.onrender.com/api/v1/hvac-coil-load?utm_source=zero.xyzChoose this endpoint when you need rigorous ASHRAE-compliant psychrometric coil load calculations with full step-by-step workings, support for both IP and SI units, elevation correction, condensate calculation, outdoor/return air mixing, or reverse-solving (finding leaving conditions from known loads). Prefer over manual calculations or generic psychrometric tools when you need tons, SHR, condensate, and a complete audit trail of every equation used. Use sibling psychrometric endpoint for single-state property lookups without coil load context.
| Field | Type | Description |
|---|---|---|
| mode | string | When solving a state from loads: cooling (default) removes heat, heating adds it. Detected automatically when both states are given. |
| units | string | "IP" (°F, CFM, in, BTU) or "SI" (°C, L/s, mm, kW). Default IP. Applies to inputs and results. |
| airflow | number | Total airflow through the coil: CFM (IP) or L/s (SI). |
| leaving | object | Air leaving the coil: two properties, like `entering`. |
| entering | object | Air entering the coil: exactly two of dry_bulb, wet_bulb, dew_point, relative_humidity (%), humidity_ratio (lb/lb or g/kg), enthalpy (BTU/lb or kJ/kg), grains (gr/lb), in `units`. With outdoor_air and return_air but no outdoor air amount, it is the mixed air and the outdoor air % is back-calculated. |
| elevation | number | Site elevation, ft (IP) or m (SI); sets the atmospheric pressure. Default 0 (sea level). |
| return_air | object | Return air (two properties, like `entering`). |
| latent_load | number | Coil latent load, MBH or kW (default 0 when only sensible_load is given). |
| outdoor_air | object | Outdoor air (two properties, like `entering`), mixed with return_air ahead of the coil. |
| sensible_load | number | Coil sensible load, MBH (IP) or kW (SI): with one state, solves the other. |
| outdoor_airflow | number | Outdoor airflow, CFM or L/s (instead of outdoor_air_percent). |
| outdoor_air_percent | number | Outdoor air share of the total airflow, %. |
{
"type": "json",
"example": {
"mode": "cooling",
"loads": {
"tons": 32.736,
"total": 392.833,
"latent": 122.833,
"sensible": 270,
"sensible_heat_ratio": 0.687,
"total_from_enthalpy": 399.538
},
"notes": [],
"steps": [
{
"step": "Atmospheric pressure",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics, Eq. 3",
"calculation": "p = 14.696 × (1 − 6.8754×10⁻⁶ × Z)^5.2559 = 14.696 × (1 − 6.8754×10⁻⁶ × 0)^5.2559 = 14.6960 psia"
},
{
"step": "Entering air state",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics",
"calculation": "pws(67.00 °F wet bulb) = 0.32772 psia (ASHRAE Ch. 1 Eq. 6)"
},
{
"step": "Entering air state",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics",
"calculation": "Ws* = 0.621945 × pws / (p − pws) = 0.014185 lb/lb (saturated at the wet bulb)"
}
],
"units": "IP",
"mixing": null,
"airflow": 10000,
"leaving": {
"grains": 60.42,
"density": 0.07667,
"dry_bulb": 55,
"enthalpy": 22.569,
"wet_bulb": 54,
"dew_point": 53.29,
"humidity_ratio": 0.008631,
"vapor_pressure": 0.20116,
"specific_volume": 13.1549,
"relative_humidity": 93.95
},
"entering": {
"grains": 78.18,
"density": 0.07301,
"dry_bulb": 80,
"enthalpy": 31.447,
"wet_bulb": 67,
"dew_point": 60.32,
"humidity_ratio": 0.011169,
"vapor_pressure": 0.25926,
"specific_volume": 13.8494,
"relative_humidity": 51.1
},
"pressure": 14.696,
"elevation": 0,
"condensate": 13.69,
"next_calls": [
{
"why": "What duct size carries 10000 CFM at 0.08 in. w.g. / 100 ft?",
"tool": "hvac_duct_size",
"price": "$0.002",
"arguments": {
"units": "IP",
"airflow": 10000,
"friction_rate": 0.08
}
}
],
"references": [
"ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics",
"Standard-air load equations: Qs = 1.08·CFM·ΔT, Ql = 4840·CFM·ΔW, Qt = 4.5·CFM·Δh"
],
"solved_for": "loads",
"unit_labels": {
"area": "ft²",
"load": "MBH (1,000 BTU/h)",
"grains": "gr / lb dry air",
"length": "in",
"airflow": "CFM",
"density": "lb / ft³",
"enthalpy": "BTU / lb dry air",
"pressure": "psia",
"velocity": "FPM",
"elevation": "ft",
"condensate": "gal / h",
"temperature": "°F",
"friction_rate": "in. w.g. / 100 ft",
"humidity_ratio": "lb water / lb dry air",
"specific_volume": "ft³ / lb dry air",
"relative_humidity": "%",
"velocity_pressure": "in. w.g."
}
}
}No reviews yet. Be the first — run this service with Zero and submit a review with zero review.