HVAC Psychrometrics Calculator is a paid API for AI agents from x402-agent-api.onrender.com, paid per call via x402, $0.002/call, status unknown (last checked 2026-10-10).
Calculates the full psychrometric state of moist air (dry-bulb, wet-bulb, dew point, enthalpy, humidity ratio, density, etc.) from any two known properties, with every ASHRAE-referenced calculation step shown
SEC filings and web data for AI agents: read any section of a US public company's 10-K or 10-Q (risk factors, MD&A, …) since 2001, see what changed in it since last year, its latest 8-K events and press releases, and a free index of its filings; turn any web page into clean Markdown; profile a domain's email setup; HVAC engineering calculations (psychrometrics, coil loads, duct sizing) with every step shown. No accounts or API keys: pay per call in USDC with x402. Discovery endpoints are free; paid endpoints use the x402 v2 protocol with USDC on Base. Call a paid endpoint, receive 402 with a PAYMENT-REQUIRED header, sign the payment, and retry with PAYMENT-SIGNATURE. Libraries such as @x402/fetch do this transparently. Which tool: What filings does a company have? Which year's report or which 8-K do I want? → sec_list_filings (free). What are a company's risk factors? What did management say in the MD&A? What was in an earlier year's report? → sec_filing_section ($0.01). What changed in a company's risk factors (or MD&A, business, legal proceedings) since last year? Which new risks were added? → sec_section_changes ($0.04). I need several sections of the same report (e.g. risk factors and MD&A). → sec_filing_sections ($0.015). What are a company's revenue, profit, EPS, cash, debt and free cash flow over the last years or quarters? → sec_financials ($0.005). Are a company's insiders (CEO, CFO, directors) buying or selling its stock? → sec_insider_trades ($0.005). What happened at a company lately: earnings, CEO/CFO changes, acquisitions, cybersecurity incidents? → sec_recent_events ($0.01). Which companies' SEC filings mention a phrase ("material weakness", "tariff", a product or a person)? → sec_full_text_search ($0.01). Who is this company (from a domain, name or ticker): what it does, HQ, founders, CEO, employees, ticker? → company_profile ($0.01). Is this person, company or crypto wallet on a US sanctions (OFAC) list? → sanctions_screen ($0.005). Where are US interest rates, inflation and unemployment right now? → economic_indicators ($0.003). What does this web page, article, PDF, feed or documentation say? → scrape_markdown ($0.002). Read several pages at once, or find a site's pages (pricing, docs, blog) first? → site_map ($0.002). Is this email address real and safe to send to? → email_verify ($0.002). Who hosts a company's email, is SPF/DMARC set up, which SaaS does it use? → domain_enrich ($0.004). HVAC: what are the dew point, enthalpy, RH and humidity ratio of air (from any two properties, at any elevation)? → hvac_psychrometrics ($0.002). HVAC: what is the cooling or heating coil load (sensible, latent, tons), or the mixed air with outdoor air? → hvac_coil_load ($0.002). HVAC: what size duct for this airflow (equal friction or velocity), or what friction and velocity in this duct? → hvac_duct_size ($0.002). Inputs are forgiving: name a company by ticker, CIK or name; sections as "Risk Factors", "MD&A" or "Item 1A"; 8-K events as codes (5.02) or words (earnings, executive changes); unknown fields are ignored. Invalid input returns a valid example, and failed calls are never charged. Every paid result ends with `next_calls`: the natural follow-up questions as ready-to-send calls with their price. Live reliability (answers, failures and latency per tool) is published at /status.
Returns the complete psychrometric state of moist air including dry-bulb, wet-bulb, dew-point, relative humidity, enthalpy, humidity ratio, grains per pound, specific volume, vapor pressure, and density — along with atmospheric pressure for the given elevation, step-by-step ASHRAE-referenced calculations, unit labels, and suggested next API calls (e.g. coil load calculation).
POSThttps://x402-agent-api.onrender.com/api/v1/hvac-psychrometrics?utm_source=zero.xyzChoose this endpoint when you need accurate ASHRAE-compliant psychrometric calculations with full step-by-step derivations shown, especially for HVAC design, load calculations, or engineering documentation. It supports both IP and SI unit systems and handles elevation-adjusted atmospheric pressure. Use it before calling the coil load or duct sizing endpoints when you need to establish the entering/leaving air state. Prefer this over generic calculators when ASHRAE Handbook references and intermediate calculation steps are required for engineering compliance.
| Field | Type | Description |
|---|---|---|
| units | string | "IP" (°F, CFM, in, BTU) or "SI" (°C, L/s, mm, kW). Default IP. Applies to inputs and results. |
| grains | number | Moisture in grains per lb dry air (gr/lb), in either unit system (7,000 gr = 1 lb). |
| dry_bulb | number | Dry-bulb temperature, °F (IP) or °C (SI). |
| enthalpy | number | Enthalpy: BTU per lb dry air (IP) or kJ/kg dry air (SI). |
| wet_bulb | number | Wet-bulb temperature, °F or °C. |
| dew_point | number | Dew-point temperature, °F or °C. |
| elevation | number | Site elevation, ft (IP) or m (SI); sets the atmospheric pressure. Default 0 (sea level). |
| humidity_ratio | number | Humidity ratio: lb water per lb dry air (IP, e.g. 0.0100) or g/kg (SI, e.g. 10.0). |
| relative_humidity | number | Relative humidity, % (0-100). |
{
"type": "json",
"example": {
"notes": [],
"state": {
"grains": 98.46,
"density": 0.07092,
"dry_bulb": 95,
"enthalpy": 38.316,
"wet_bulb": 75,
"dew_point": 66.76,
"humidity_ratio": 0.014065,
"vapor_pressure": 0.325,
"specific_volume": 14.2995,
"relative_humidity": 39.82
},
"steps": [
{
"step": "Atmospheric pressure",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics, Eq. 3",
"calculation": "p = 14.696 × (1 − 6.8754×10⁻⁶ × Z)^5.2559 = 14.696 × (1 − 6.8754×10⁻⁶ × 0)^5.2559 = 14.6960 psia"
},
{
"step": "Humidity ratio",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics",
"calculation": "pws(75.00 °F wet bulb) = 0.43007 psia (ASHRAE Ch. 1 Eq. 6)"
},
{
"step": "Humidity ratio",
"reference": "ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics",
"calculation": "Ws* = 0.621945 × pws / (p − pws) = 0.018750 lb/lb (saturated at the wet bulb)"
}
],
"units": "IP",
"pressure": 14.696,
"elevation": 0,
"next_calls": [
{
"why": "What load does a coil carry cooling this air to 55/54 °F at 1000 CFM?",
"tool": "hvac_coil_load",
"price": "$0.002",
"arguments": {
"units": "IP",
"airflow": 1000,
"leaving": {
"dry_bulb": 55,
"wet_bulb": 54
},
"entering": {
"dry_bulb": 95,
"wet_bulb": 75
}
}
}
],
"references": [
"ASHRAE Handbook—Fundamentals (2021), Ch. 1 Psychrometrics"
],
"inputs_used": {
"dry_bulb": 95,
"wet_bulb": 75
},
"unit_labels": {
"area": "ft²",
"load": "MBH (1,000 BTU/h)",
"grains": "gr / lb dry air",
"length": "in",
"airflow": "CFM",
"density": "lb / ft³",
"enthalpy": "BTU / lb dry air",
"pressure": "psia",
"velocity": "FPM",
"elevation": "ft",
"condensate": "gal / h",
"temperature": "°F",
"friction_rate": "in. w.g. / 100 ft",
"humidity_ratio": "lb water / lb dry air",
"specific_volume": "ft³ / lb dry air",
"relative_humidity": "%",
"velocity_pressure": "in. w.g."
}
}
}No reviews yet. Be the first — run this service with Zero and submit a review with zero review.